I’ve recently been seeing engineers choosing what I feel are inappropriate Manning’s “n” coefficients for sewer design.  Some choose too conservative values, while others don’t understand that long term creep within the pipe wall may adversely affect the hydraulic performance of certain pipe types.  A few things to consider are as follows:

  1. Corrugated Metal Pipe (CMP):  Not all CMP has a Manning’s n value of 0.024!  This value is mostly attributed to the old style riveted, or annular, CMP.  The most common CMP produced today is helically wrapped into diameters ranging from 6” to 144” and larger.  The helical nature of the modern CMP allows for much better flow characteristics that can result in much smoother Manning’s n values (e.g. 15” Diameter ½ inch corrugation has a n value = 0.012).  More importantly, within the helical family of CMP there exists a unique corrugation referred to as “spiral ribbed” CMP where the Manning’s n value = 0.012 for all diameters provided.  A simple chart for guidance is below:



  2. Sanitary Sewer:  Not all thermoplastic pipes in the sanitary world are equal.  Many know that Polyvinyl Chloride (PVC) has a Manning’s n value of 0.009, but they conservatively use 0.012/0.013 based on Reinforced Concrete Pipe’s historical values after adjusting for sliming of the pipe wall and joints.  Since PVC is highly resistant to sliming, this is considered as an overly conservative number, but we know it will work.

    Many mistakenly think all thermoplastic pipe will have the same Manning’s n value as PVC in the short term and long term.  Specifier beware.   Some materials, like Polypropylene, have a much lower elastic modulus and tensile strength, can produce laboratory tests showing the Manning’s n = 0.010/0.011, but after installation the inner wall can experience local buckling that dramatically increases n values as high as 0.015 to 0.020.  See example picture below:


    Polypropylene Sewer Pipe Inner Wall Buckling

  3. PVC vs. RCP:  Many specifiers don’t realize they can possibly reduce their diameters 3” to 6” by using PVC storm sewer pipes vs. RCP.  When using Hydraulic Conveyance Values (C1) you get the following tables when using PVC n=0.009 vs. RCP n=0.013 respectively.

  C1 Values = (1.486/n) (A) (R2/3)

Diameter PVC (C1) RCP (C1) Same Diameter Variance PVC vs 3” Larger RCP Diameter Variance
12” 51.4 35.7 144% 79%
15” 93.3 64.7 144% 89%
18” 151.7 105 144% 96%
21” 228.8 158 145% 101%
24” 326.7 226 145% 105%
27” 447.3 310 144% 109%
30” 592.4 410 144% 89%
36” 963.4 666 145% 89%
42” - 1006   96%

You can also consider replacing RCP Pipe Arch with PVC pipe.

C1 Values = (1.486/n) (A) (R2/3)

Diameter RCP Pipe Arch Dimension PVC (C1) RCP Pipe Arch (C1) Variance Distance from invert to top of PVC Distance from invert to top of RCP P. Arch
12” 18 x 11” 51.4 50 103% 12.26” 13.25”
15” 22 x 13.5” 93.3 84 111% 15” 16”
18” 26 x 15.5” 151.7 127 119% 18.35” 18.25”
21” 28.5 x 18” 228.8 187 122% 21.67” 21”
24” 36.25 x 22.5” 326.7 339 96% 24.55” 26”
30” 43.75 x 22.5” 592.4 566 105% 30.81” 30.63”
36” 51.13 x 31.31” 963.4 866 111% 37.11” 35.81”


Consider these tips when designing your sewer projects moving forward.

Written by:

Author Biography

Andrew M. Jenkins, holds a Bachelor of Science degree in Engineering from Missouri University of Science and Technology (Rolla). Jenkins' experience comes from 19 years in the petroleum, mining, and civil engineering industries. He can be contacted at ajenkins@conteches.com.

 

 

Post Rating

Comments

Thursday, September 21, 2017 1:48 PM
Hi Andrew:

it is a pleasure to read such a wonderful technical article from alumni from the University of Missouri-Rolla. I graduated from this wonderful Rolla School of Mines many years ago and my education at this institution has enabled me to work as a Civil Engineer for private and public sectors throughout the Midwest and the Pacific NW.

Please feel free to contact me at the e-mail above. I would like to know if you have a chart that you could send me showing the n value for PVC pipe VS RCP. PVC and HDPE pipes are widely used in the Pacific NW but RCP is not very popular here. While I worked in Kansas City for many years, the only pipes allowed were RCP and CMP with Bituminous Coating.

I look forward to hearing from you,

Shawn Pourazari, P.E.

Post Comment

Name (required)

Email (required)

Website

CAPTCHA image
Enter the code shown above:

Text/HTML